OUR OTHER ACTIVITIES |
 |
CONSULTANCY IN CONSTRUCTION CHEMICALS |
 |
ENGINEERING & CONTRACTING |
 |
SEALANT APPLICATION |
 |
PRESSURE GROUTING BY HYDRAULIC / PNEUMATIC PUMPS |
 |
ALL TYPES OF HYBUILD / PROTECTIVE COATING EQUIPPED MANUFACTURING BASE FOR MECHANICAL ENGINEERING & EPE FOAM PRODUCT |
|
|
 |
|
Compliance with International Standards and also with M.O.S.T. Specifications, AAI & MES
specifications
Versatile application in roads , runways, buildings, bridges , structures |
Descriptions :
This is a microcellular, closed cell, PE foam Board being manufactured in various grades, size & shapes to meet various requirements of construction industry. |
Technical Compliance :
Meets Specification of Highway works As per Vol : I-clause 1015 B.S. 5628 / B.S. Specification clause No. 2630 and (M.O.S.T.) IS 1838* |
Advantages :
1) Fuel / Solvent / Water / Good Weather Resistant.
2) Excellent movement accomodations.
3) Negligible water absoption & long life. |
Uses :
As a filler material in expansion joints & movement joints of Road, Bridges, Buildings, Tunnels, Water Retaining Structure etc. |
Technical Data for H-20 / 100-Grade |
Density |
: |
100 ± 10 Kg. / M.³ |
Tensile strenght |
: |
12 Kg. / sq.cm. |
Elongation |
: |
110% |
Recovery at 50% compression |
: |
average 97% (As per M.O.S.T. test procedures) |
Water absorption |
: |
0.02% ( negligible) |
Temperature range |
: |
- 40 to 100°C |
Fuel / Solvent / Chemical resistance |
: |
Excellent (Similar to LDPE) |
Reaction / adhesion to Sealents |
: |
Totally innert with all type of sealent. |
Weathering conditions |
: |
Passes Weatherability test. |
Compression loading |
: |
Satisfies B.S. 5628 Code of practice. |
|
 |
Technical Specifications for full range of our
product : |
Hardness |
: |
20 ± 5 |
Density |
: |
100 ± 10 Kg./ M.³ |
Width |
: |
6 mm. to 1000 mm. |
Thickness in mm |
: |
6/10/12/15/18/20/25/30/35/40/45/50 |
Length |
: |
1m, 2m, 7.5m, 8.5m, 9.5m |
Special sizes can also be manufactured on special orders. |
|
|
 |
 |
 |
FILLER BOARDS ON PAVEMENTS |
|
|
 |
 |
 |
FILLER BOARDS IN BUILDINGS |
FILLER BOARDS IN JOINTS |
FILLER BOARDS IN JOINTS |
|
|
|
|